Light X-Ray Shielding Automatic Door | Lead-Equivalent Radiation Protection
Smart Radiation Protection: Light X-Ray Shielding Automatic Doors The Light X-Ray Shielding Automatic Door is the modern answer to radiation protection in medical imaging — a door that combines lead-lined shielding with full automation and certified safety compliance. Designed for X-ray rooms, CT ...
Smart Radiation Protection: Light X-Ray Shielding Automatic Doors
The Light X-Ray Shielding Automatic Door is the modern answer to radiation protection in medical imaging — a door that combines lead-lined shielding with full automation and certified safety compliance. Designed for X-ray rooms, CT suites, DR systems, dental radiology, and cardiac catheterization labs, this door blocks harmful radiation while opening hands-free for patients, gurneys, and staff — protecting everyone in the department without slowing down clinical workflow.


| Opening speed | 250–500mm/s (adjustable) |
| Closing speed | 250–500mm/s (adjustable) |
| Hold-open time | 2–20 s (adjustable) |
| Closing force (F) | >70 N |
| Manual pushing force | <100N |
| Total power consumption | <150W |
Lead-Lined Shielding — 1-3.1 mmPb Protection Against Harmful Rays
The door leaf is lined with a lead shielding layer rated at 1 - 3.1 mmPb, effectively preventing a wide range of harmful radiation from harming the human body. Both primary beam and scattered radiation are contained within the imaging room, protecting staff, patients, and passersby in adjacent areas.
CDC & Nuclear Safety Medical Testing Certified
Passed the testing requirements of the Chinese Center for Disease Control and Prevention and nuclear safety medical evaluation, fully compliant with X-ray protection requirements. The shielding performance is documented with test reports — providing audit-ready radiation safety evidence for hospital commissioning and regulatory inspection.
Clean-Sealed Power Beam & Profiles — Hospital-Grade Cleanliness
The door's power beam and profiles are equipped with sealing strips, ensuring a rational, reliable structure that meets the cleanliness requirements of hospitals and medical facilities. Dust, drafts, and airborne particles are kept out of the imaging suite, maintaining a stable and hygienic environment around sensitive imaging equipment.
Medical Electrical Safety-Compliant Control System
The control system meets medical electrical safety design requirements, delivering safe and stable operation. Designed in accordance with IEC 60601-1, the drive electronics, insulation, and protective circuits ensure reliable performance around patients and medical staff.
Zero Electromagnetic Interference (EMC) to Other Equipment
The door produces no electromagnetic interference affecting other devices in the same environment. Complying with IEC 60601-1-2, the motor drive and control board are fully shielded and filtered — safe to operate alongside imaging systems, patient monitors, and life-support equipment without causing disruption.
Hermetic or Sliding — Elegant & Versatile
Available in hermetic (airtight) or sliding configurations, with a beautiful, elegant appearance. Choose the hermetic type for pressure-sealed radiation suites or the sliding type for space-saving high-traffic entrances — both integrate seamlessly into modern hospital interiors.
Applications:





